Item Number | 10074137

MSA Altair Pro O2 Oxygen Single Gas Detector

  • Size:3.4”L x 2.0”W x 1.0”H
  • Weight: 4.0 oz including clip
  • Case Material: Polycarbonate with rubber overmolding
  • Event Log: Equipped with standard event data logging of no less than 50 events before overwriting oldest logged events
  • Data Log: Equipped with standard data logging feature
  • Environmental Protection: Rated to IP 67 protection levels for dust/water ingress
  • Alarms: Equipped with visual, vibrating and audible alarms. Audible alarms sound at an average of 95 dB @ 1 foot.Visual alarms are bright and viewable from top, front and sides.
  • Bump Test: A checkmark is displayed to indicate a successful bump test for 24 hours after conducting the bump test.
  • Operating Lifetime: Typical installed battery life 9000 hours. Sensor life is two years.
  • Confidence Flash: Unit periodically (average every 60 seconds) confirms proper operation by: Confidence flash on Alarm LEDs; Confidence dot on display (heartbeat indicator)
  • Backlight: Activated at the start of any alarm situation or by a simple press of a button
  • Monitoring Range: 0-30% Vol
  • Resolution: 0.1 %VOL
  • Standard Alarm Points – Low: 19.50% High: 23.00%
  • Battery: Replaceable CR2 lithium battery. Only Energizer EL1CR2, Varta CR2, or Panasonic CR2 batteries should be used.
  • Calibration: Zeroes and calibrated easily using one button
  • Calibration Set Point: Calibration gas concentration set points are user-adjustable
  • Data Storage Capacity: 50 past events
  • Record Content: Event log entries shall contain as a minimum
  • Alarm: type, value, time and date
  • Alarm clear: type, value, time and date
  • Calibration: pass/fail, time and date
  • Bump: pass/fail, time and date
  • Error non-shutdown: error type, time and date
  • End of life: reason, alarm minutes, months life, time and date
  • Datalogging: Equipped with datalogging function. Default setting is three minute peak readings. This sample rate is configurable via PC 15 seconds to 15 minute peaks or one minute peak average.
  • Certifications: US and Canada Class 1, Division 1, Groups A, B, C and D
  • Temperature: Normal Operation: -20 to 50 °C
  • Humidity: 10-95% RH non-condensing
  • Maintenance: Replaceable sensors and battery
  • Warranty: Full two-year warranty. Does not cover battery